We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Fire Service Act Hazardous Materials Verification Test.
ipros is IPROS GMS ・ IPROS One of the largest technical database sites in Japan that collects information on.

Fire Service Act Hazardous Materials Verification Test - List of Manufacturers, Suppliers, Companies and Products | IPROS GMS

Fire Service Act Hazardous Materials Verification Test Product List

1~8 item / All 8 items

Displayed results

[Free Seminar Now Streaming] What is the Fire Service Act Hazardous Materials Confirmation Test?

Clear explanations from Class 1 to Class 6, along with actual exam footage! (Approximately 15 minutes)

■Overview The regulation of hazardous materials under the Fire Service Act is determined entirely through testing, including the classification of materials as hazardous or non-hazardous and the determination of specified quantities. This seminar will clearly explain basic information about the Fire Service Act and testing methods, and you will also be able to view actual test footage. ■Seminar Content (1) Introduction - What is the Fire Service Act? What are hazardous materials? (2) Introduction to Testing - Properties of hazardous materials and testing methods - Prioritization of hazardous materials (3) Regarding Requests - Necessary information, deadlines (4) Conclusion ■How to View You can watch the seminar by clicking "Watch the Seminar Here." No special software download is required. ■Recommended For - Those who are storing or transporting hazardous materials domestically or plan to do so - Those who want to see test footage - Those who want to know the procedure for requesting tests ★This seminar is available for a limited time only ★In addition to the Fire Service Act hazardous materials confirmation test, "Introduction to Hazard Assessment Testing Facilities," "Dust Explosion Testing," and "Hazard Assessment of Chemical Substances" are also currently available. ■Public Viewing Period March 14, 2022 - May 31, 2022 (planned) *Please note that the public viewing period for this seminar may change without notice.

  • Contract measurement
  • Contract Analysis
  • Contract Inspection
  • Fire Service Act Hazardous Materials Verification Test

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Determination of Hazardous Materials under the Fire Service Act (Type 1)

A solid that causes extremely intense combustion when mixed with combustible materials and decomposes due to heat, etc.!

Our company conducts "Fire Service Law Hazardous Material Assessment (Class 1)." Class 1 hazardous materials under the Fire Service Law (oxidizing solids) are solids that have the property of oxidizing other substances and pose a risk of extremely vigorous combustion when mixed with combustible materials and decomposed by heat, etc. Examples include chlorates, perchlorates, peracids, chromates, and other substances specified by government ordinance. 【Target Substance Names (partial)】 ■ Chlorates ■ Perchlorates ■ Inorganic peroxides ■ Hypochlorites ■ Bromates *For more details, please refer to the related links or feel free to contact us.

  • Other contract services
  • Fire Service Act Hazardous Materials Verification Test

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Determination of Hazardous Materials under the Fire Service Act (Category III)

A substance that ignites spontaneously when exposed to air, ignites upon contact with water, or generates flammable gases!

Our company conducts "Fire Service Law Hazardous Material Assessment (Class 3)." Class 3 hazardous materials under the Fire Service Law (self-igniting substances and water-reactive substances, solid or liquid) are those that have the potential to ignite spontaneously when exposed to air, or those that ignite upon contact with water or generate flammable gases. Examples of target substances include potassium, sodium, and alkyl aluminum. 【Target Substance Names (Partial)】 ■ Potassium ■ Sodium ■ Alkyl Aluminum ■ Alkyl Lithium ■ Yellow Phosphorus ■ Alkali Metals (excluding potassium and sodium) and Alkaline Earth Metals *For more details, please refer to the related links or feel free to contact us.

  • Other contract services
  • Fire Service Act Hazardous Materials Verification Test

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Determination of Hazardous Materials under the Fire Service Act (Category 4)

Determination of flammable liquids! (Limited to those that are liquid at 20°C and 1 atmosphere for Class III petroleum products, Class IV petroleum products, and animal and vegetable oils)

Our company conducts "Fire Service Law Hazardous Material Assessment (Category 4)." Category 4 hazardous materials under the Fire Service Law refer to liquids that are flammable (limited to those that are liquid at 20°C and 1 atmosphere pressure, including Class 3 petroleum, Class 4 petroleum, and animal and vegetable oils). Examples of target substances include special flammable materials, Class 1 petroleum, and alcohols. 【Names of Target Substances (Partial)】 ■ Special flammable materials ■ Class 1 petroleum ■ Alcohols ■ Class 2 petroleum ■ Class 3 petroleum *For more details, please refer to the related links or feel free to contact us.

  • Other contract services
  • Fire Service Act Hazardous Materials Verification Test

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Determination of Hazardous Materials (Category II) under the Fire Service Act

Solid materials that are easily ignited by flames or relatively low temperatures (below 40°C)!

Our company conducts "Fire Service Law Hazardous Material Assessment (Category II)." Category II hazardous materials under the Fire Service Law (flammable solids) are solids that are easily ignited by flames or solids that can ignite at relatively low temperatures (below 40°C). Examples of target substances include phosphorus sulfide, red phosphorus, sulfur, iron powder, metal powders, and magnesium, among others specified by government ordinance. 【Examples of Target Substances (Partial)】 ■ Phosphorus sulfide ■ Red phosphorus ■ Sulfur ■ Iron powder ■ Metal powders ■ Magnesium *For more details, please refer to the related links or feel free to contact us.

  • Other contract services
  • Fire Service Act Hazardous Materials Verification Test

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Determination of Hazardous Materials under the Fire Service Act (Category 5)

A substance that generates a large amount of heat at relatively low temperatures due to self-reactions such as thermal decomposition, or reacts explosively!

Our company conducts "Fire Service Law Hazardous Material Assessment (Class 5)." Class 5 hazardous materials under the Fire Service Law (self-reactive substances, solid or liquid) refer to those that generate a large amount of heat at relatively low temperatures due to self-reaction such as thermal decomposition, or those that react explosively. Examples of target substances include organic peroxides, nitrate esters, and nitro compounds. 【Examples of Target Substances (Partial)】 ■ Organic peroxides ■ Nitrate esters ■ Nitro compounds ■ Nitroso compounds ■ Azo compounds ■ Diazo compounds *For more details, please refer to the related links or feel free to contact us.

  • Other contract services
  • Fire Service Act Hazardous Materials Verification Test

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Determination of Hazardous Materials under the Fire Service Act (Category 6)

It is a liquid that does not burn itself but has the property of promoting the combustion of other combustible materials mixed with it!

Our company conducts "Fire Service Law Hazardous Material Assessment (Category 6)." Category 6 hazardous materials under the Fire Service Law (oxidizing liquids) refer to liquids that do not burn themselves but have the property of promoting the combustion of other flammable materials with which they are mixed. Examples of target substances include perchloric acid, hydrogen peroxide, and nitric acid. 【Target Substance Names】 ■ Perchloric acid ■ Hydrogen peroxide ■ Nitric acid ■ Other substances specified by government ordinance (halogenated compounds) ■ Any of the above-mentioned substances *For more details, please refer to the related links or feel free to contact us.

  • Other contract services
  • Fire Service Act Hazardous Materials Verification Test

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Fire Law Hazardous Materials Verification Test

Leave the verification tests that require appropriate testing equipment and specialized knowledge and experience to us!

At Japan Carlit Co., Ltd., we offer "Fire Service Law Hazardous Material Confirmation Testing." Hazardous materials are classified into categories 1 through 6 based on their properties, and confirmation tests are conducted for mixtures that contain even a small amount of substances designated as hazardous materials. Based on the results, the degree of hazard is regulated by rank. To conduct the confirmation tests, appropriate testing equipment and specialized knowledge and experience are required. For inquiries, estimates, or site visits regarding the "Fire Service Law Hazardous Material Confirmation Testing," please contact us. 【Types and Properties】 ■ Category 1: Oxidizing solids ■ Category 2: Flammable solids ■ Category 3: Self-heating substances / Water-reactive substances ■ Category 4: Flammable liquids ■ Category 5: Self-reactive substances ■ Category 6: Oxidizing liquids ■ Designated flammable materials *For more details, please refer to the PDF document or feel free to contact us.

  • Public Testing/Laboratory
  • Contract measurement
  • Contract Inspection
  • Fire Service Act Hazardous Materials Verification Test

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Related Categories of Fire Service Act Hazardous Materials Verification Test